Autonics ATN Series General Specifications |
||||
Model |
AT8N-[] |
AT11EN-[] |
AT11DN-[] |
|
Function |
Multi function timer |
|||
Control time setting range |
0.05 sec. to 100 hour |
|||
Power supply |
• 100-240VAC 50/60Hz, 24-240VDC |
|||
Allowable voltage range |
90 to 110% of rated voltage |
|||
Power consumption |
• Max. 4.3VA (100-240VAC), Max. 2W |
• Max. 3.5VA (100-240VAC), Max. 1.5W |
||
Reset time |
Max. 100ms |
|||
Min. input signal width |
START |
— |
Min. 50ms |
|
INHIBIT |
||||
RESET |
||||
Input |
START |
— |
No-voltage input – Short-circuit |
|
INHIBIT |
||||
RESET |
||||
Timing operation |
Power ON start type |
Signal ON Start type |
||
Control output |
Contact type |
Time limit DPDT (2c), |
Time limit SPDT (1c), |
Time limit DPDT (2c) |
Contact capacity |
250VAC 5A resistive load |
|||
Relay life cycle |
Mechanical |
Min. 10,000,000 operations |
||
Electrical |
Min. 100,000 operations (250VAC 5A |
|||
Repeat error |
Max. ±0.2% ±10ms |
|||
SET error |
Max. ±5% ±50ms |
|||
Voltage error |
Max. ±0.5% |
|||
Temperature error |
Max. ±2% |
|||
Insulation resistance |
Min. 100MΩ (at 500VDC megger) |
|||
Dielectric strength |
2000VAC 50/60Hz for 1 minute |
|||
Environment |
Ambient temperature |
-10 to 55°C, storage: -25 to 65°C |
||
Ambient humidity |
35 to 85%RH |
|||
Accessory |
Bracket |
|||
Unit weight |
Approx. 90g |
|||
*Environment resistance is rated atno freezing or condensation. |